ALTROZ SERVICE MANUAL
ELECTRICAL 45 10. POWER SOCKETS One-power sockets of 12V DC-10 amps each on center console. This is for connecting loads up to 10A maximum. To use this socket, open the cap first. Location – F ront center console Rear console REMOVAL AND REFITMENT 1. Remove the bezel holding Power socket 2. Pry out Socket holder assembly from bezel 3. Remove electrical connections from power socket REFITMENT Install the power socket in the reverse order of removal. 11. GLOWPLUG CONTROL UNIT Location: The Glow Plug Interface Unit mounted on water channel RHD OPERATIONAL DESCRIPTION The aim of Glow Plug Interface Unit (GPIU) is to achieve high degree of flexibility in driving the glow plugs that are included in a standard EMS system for diesel engines. It is evident that the requirement for GPIU depends from the driving characteristics required by the glow plugs. In a modern direct injection diesel engine the function developed by glow plug may be summarized as follows: Auxiliary starting device Cold diesel engines due to high levels of internal frictions & thermal losses are reluctant to start. Often need of auxiliary devices like glow plugs are the only method to guarantee engine start. The glow plug power dissipation increases the combustion chamber temperature allowing the air fuel mixture to reach its self-ignition condition.