TIAGO TIGOR CNG - SERVICE MANUAL

HVAC 47  Keep a suitable container below it to collect the coolant that will flow out. 7. Remove mountings on HVAC unit and take out the HVAC unit. FITMENT For fitment follow the reverse procedure of removal. I. CONDENSER SEALING DUCT REMOVAL 1. Open the bonnet. 2. Remove the bumper. (Refer Body section). 3. Remove horns from both ends. 4. Remove mounting screws on sealing Assembly & take out. FITMENT For fitment follow the reverse procedure of removal . J. CONDENSER REMOVAL 1. Remove the radiator. (Refer Radiator removal procedure in Engine Draft)) 2. Remove the 4 condenser mountings on radiator and take it out. CAUTION: Never leave the condenser lines open immediately cover them with caps, otherwise the desiccant which is in-built in the condenser may absorb the moisture from surrounding air and get contaminated. FITMENT For fitment follow the reverse procedure of removal.