TIGOR AMT

AMT KIT 22 connections, sensors and gasket from accidental contact.  Always protect ‘Transmission Control Unit’ from exposition to water, humidity or other foreign materials (‘Transmission Control Unit’ is water/humidity proof only when mounted on the system).  The ‘Transmission Control Unit’ package must ensure protection against the accidental fall of tools or other pieces, in particular on the connectors and sensors.  Never use improper tool (screwdrivers, etc.) to lift and extract the ‘Transmission Control Unit’ from the electro valve block.  The surface of the electro valve block must be absolutely clean and free from oil or other polluting substances. Removal: NOTE Any extraction tool (if any) that will be developed must be submitted to ‘MAGNETI MARELLI’ approval.  Disengage the female connectors with the cables from the ‘Transmission Control Unit’.  Unscrew the four ‘Transmission Control Unit’ fixing screws with sequence indicated below.  In order to guarantee right ‘Transmission Control Unit’ translation during the dismounting, screw two 100 mm. Length M5 threaded rods in the holes previously used by ‘Transmission Control Unit’ fixing screws and shown in the picture below.  Disconnect the right ‘Transmission Control Unit’ from the electro valve block (disinsertion of all the electro valves, pressure sensor and ground tabs) with appropriate load precautions. The operation must be guaranteed by a ‘Transmission Control Unit’ translation of 90 mm (Min.) in the vertical axis direction guided by the two threaded rods (see image below). NOTE If the ‘Transmission Control Unit’ will be dismounted from ‘Electro Valve Block’ it is not allow to mount it again.