TATA BSVI Gasoline Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 1.2 Date: 18-12-2019 Prepared By: Sunita Mandlik Checked By: Yeshwant Jadhav Approved By: Satish Kumar Document Part No: 2921 02 xxx xxxx Page: 1277 of 1498 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Transfer Function of Pressure Sensor: Uout= (c1*pabs+c0).US Where, Uout = signal output voltage in V US = supply voltage in V pabs = absolute pressure in kPa c0 = -0.1/105 c1 = 0.85/105 kPa Characteristics of Pressure Sensor: Characteristics of Pressure Sensor with Supply Voltage of 5 Volts Characteristics of temperature Sensor: Resistance vs Temperature Characteristics Stand Alone Diagnosis of Sensor: 1. Give 5V Power Supply to the Sensor Supply pin and Ground to the Sensor Ground Pin 2. Keep the Sensor in a pressurized environment of 50 bar. 3. Measure the Voltage between the Sensor pressure Signal Pin and Ground, it should be 2.1 Volts approx. 4. Check the resistance between the Sensor Temperature signal pin and EMS ecu, @ Room temperature of 30 Degrees, it should be ~1080 Ohms.