ZEST BOLT Service Manual

Automated Manual Transmission 41 Hydraulic Unit/Electro hydraulic Selection Gearbox Electric Pump Assembly with Gear- box Removed Fitment: 1. Place the power unit back in its housing and tighten the screws to the prescribed torque. Component Fixing Dia Value (Nm) Electro- hydraulic selection gearbox power unit Screw 36 – 44 Place the solenoid valve unit complete with new O-ring back in its housing and tighten the relevant screws. Place the gear selection dog back in its housing and tighten the relevant screw. 1. Check that the gear engagement actuator is in “neutral” position as shown in the figure. Suitably grease the gear selection actuator dog. 1. Apply a bead of silicone sealant to the hy- draulic unit in the area shown in the fig- ure. 1. Place the solenoid valve unit (1a) back in its housing and tighten the screws (1b) to the prescribed torque. Component Fixing Dia Value (Nm) Hydraulic gear activation unit Screw M8 23 – 28 1. Rotate the gear selection actuator 90° clockwise in order to bring it to the posi-