ELECTRICAL 124 BCM SPECIFICATION: 1 Operating voltage range 8.5 V to 15.5 V DC 6.5 V to 15.5 V DC (for Hazard Functionality) 2 Operating temp range - 30 c to +85 c 3 Storage temp range - 40 c to +105 c 4 Quiescent current (No function Active) less than 1.5mA 4a Transport mode less than 0.4mA 5 BCM connector type (Header) No header; it’s part of the BCM housing itself 6 BCM connector type (Mating) Tyco make 7 Vehicle mounting location Below dash board and above glove box with metallic bracket 8 Mounting orientation Horizontal with connectors downwards – 45 degree angular from horizontal plane 9 Remote operating voltage 8.5 V to 15.5 V DC 10 Standard for hazardous material 2000/53/EC 11 Diagnostics OBD on CAN 12 Tolerances Tolerances on timing +/- 10% unless and otherwise specified