ZEST BOLT Service Manual

ELECTRICAL 104 FUEL VS RESISTANCE TABLE FOR INSTRUMENT CLUSTER LOW END SEGMENT TANK LEVEL(Lit) RESISTANCE (OHMS) BAR ON RESISTANCE(OHMS) BAR OFF RESISTANCE(OHMS) LOW FUEL WARING TT TOLERANCE(±2 OHMS) SHORT CIRCUIT 5 BLINK @ 2Hz 10 42 8 10 16 LFW OFF 9 38.2 18 20 26 LFW OFF 8 34.4 28 30 35 LFW OFF 7 30.6 37 39 44 LFW OFF 6 26.8 46 48 54 LFW OFF 5 23 56 58 64 LFW OFF 4 19.3 66 68 74 LFW OFF 3 15.5 76 78 84 LFW OFF 2 11.8 86 88 95 LFW OFF 1 8 97 99 109 LFW ON with 2nd Segment OFF 1 BAR BLINK 4 111 IGN ON LFW ON OPEN CIRCUIT 135 BLINK @ 2Hz 12.24.6 TEMPERATURE BAR GRAPH DETAILS : Temperature indication: TEMPERATURE CALIBRATION TABLE SEGMENT BAR ON TEMP. (ºC) BAR OFF TEMP. (ºC) 6seg 120 115 5seg 115 110 4seg 110 105 3seg 90 85 2seg 85 80 1seg (C) -40 NA Input type: Can Output: LED bar graph in Instrument Cluster high end. Absent in Instrument Cluster low end. ECT TT (Duel Colour)