HARRIER SERVICE MANUAL PART -1

ELECTRICAL 229 3.6 AUTO WIPE 3.6.1 Description BCM gets the auto wipe activation input from the combination switch. BCM shall communicate the analog sensitivity settings to RLS. RLS detects the intensity of rain based on these threshold values. BCM shall then activate the auto wipe function as per signals from rain sensor. 3.6.2 Conditional Requirements Activation –  IGN is ON &  Auto wipe mode is selected &  RLS sensor detects rain Deactivation – • IGN is OFF or • Auto wipe mode is deactivated or On Fault – Respective DTC logged 3.6.3 Operating Voltage Range DESCRIPTION REQUIREMENT VOLTAGE Rear Wash Control. Normal operating voltage range 9V-16V 3.6.4 Operating Temperature Range DESCRIPTION REQUIREMENT VOLTAGE Rear Wash Control. Operating temperature range -30  c to +85  c Storage temperature range: -40  c to +105  c