SAFARI

24 AIRCONDITIONING Fig. 32 6. Kinematics Assembly : The function of the kinematics assembly is to control the flapper’s movement and controls the distribution of air as required at different outlets. Fig. 31. 1. Remove the complete HVAC unit. 2. Remove the mount ing screws from the kinematics base plates. Fig. 32. Replace the required kinematics. Sr. No. Part Name 1 Blower Unit 2 Cooling and heating unit 3 Control panel 3.1 Blower switch 3.2 Fresh/ recirculation switch 3.3 A/C switch 3.4 Air mode selector 3.5 Heater mode selector 3.6 Dummy Fig. 31