SAFARI
3 GENERAL G Fig. 8 Fig. 9 Fig. 7 Precaution for Electrical circuit service : l Disconnect the negative cable of the battery while servicing the electrical parts that do not require battery power Fig. 7. l While removing the battery first disconnect the negative cable and then the positive cable. While reinstalling the battery, first connect the positive cable and then negative cable. l Be sure to turn the ignition switch off before disconnecting and connecting coupler to avoid electronic parts damage Fig. 8. l Do not touch the electrical terminals of parts which use microcomputers (e.g. electronic control units like ECM etc.) to avoid damage to these parts from static electricity from your body Fig. 8. l Always use the correct voltmeter, ohmmeter for taking measurement to avoid damage to the electronic control unit and sensors. l Make sure to insert the probe from wire harness side of the connector for taking measurement. l Make sure the connector halves are mating properly and terminals seating precisely in the connector body Fig. 9.