SAFARI
176 POSSIBLEFAULTSONSTATICTESTING(contd...) Note : For each Problem, all points respective to that S.No to be checked in order and rectified (Refer to ‘Flowchart’ sheet) SR. NO SENSOR /ACTUATOR FAULTVARIABLE FAULTDESCRIPTION TOCHECK TORECTIFY SYMPTOMS DTC CODE 14 Fan Drive P0691 F_M_FAN1_DRIVE_APV Electical Fan1 drive fault - short to ground P0692 F_M_FAN1_DRIVE_APV Electical Fan1 drive fault - short circuit P1691 F_M_FAN1_DRIVE_APV Electical Fan1 drive fault - open circuit P0693 F_M_FAN2_DRIVE_APV Electical Fan2 drive fault - short to ground P0694 F_M_FAN2_DRIVE_APV Electical Fan2 drive fault - short to ground P1693 F_M_FAN2_DRIVE_APV Electical Fan2 drive fault - short to ground 1. Relay connection 2. Electrical wiring 3. ECU connection 4. Relay malfunctioning Remove and connect again Terminal backout, wire open circuit & short circuit Connect properly Change relay 13 SERVICEandMIL Lamp P1650 F_M_CE_LAMP_APV Service lamp fault P0650 F_M_MI_LAMP_APV MIL Lamp fault 1. Electrical wiring from cluster to ECU 2. Cluster functioning Terminal backout, wire open circuit & short circuit Rectify / Change Cluster