SAFARI

ENGINE2.2LDICOR 172 Sr. Fault for Pin Fault Service MILLamp Fault code Symptoms Tocheck To rectify No the sensor Description Lamp - EGRFlow P0400 Reduced torque 3. Vacuum connections Ensureproper connections to malfunction from/ toEVRV EGR,VGTandIntakethrottle EVRVs 4.EGRvalvecondition Check for proper functioning ofEGRvalve 5. Electrical connections Ensureproper connectionand toEVRV wiring 6. Vacuum tube condition Ensurenokinkor leakage 7. Insufficient vacuum, Donecessary repair check whether direction ofNRV isproper. 17 EVRVActuator - OpenCircuit/ P2141 1. Vacuumconnection Ensure no leakage / proper Looseconnector from reservoir connection 2.Checkvalve Ensureproperassembly - EGRFlow P0400 Reduced torque 3. Vacuumconnections Ensureproper connections to malfunction from/ toEVRV EGR,VGTandIntakethrottle EVRVs 18 Fans OpenCircuit P1691/P1693 1.Relayconnection Removeandconnect again relay 255 Short circuit P0693 Fans run at iginitionON 2. Electrical wiring Terminal backout, wire open to -ve/+ve circuit & short circuit 256 Short circuit to -ve/+ve P0691 2. Electrical wiring Connect properly 4. Relaymalfunctioning Changerelay 19 AC Open Circuit P1646 1. Relay connection Remove and connect again relay 258 Short circuit to -ve/+ve P0646/P0647 AC compressor runs 2. Electrical wiring Terminal backout, wire open @ key on ac off circuit & short circuit 2. Electrical wiring Connect properly 4. Relay malfunctioning Change relay