NEXON EV SERVICE MANUAL

FATC 51 K. CONDENSER SEALING DUCT REMOVAL 1. Remove the bumper (Refer Body section). 2. Open the bonnet. 3. Remove horns from both ends. 4. Loosen and remove mounting screws. FITMENT Follow the reverse procedure of removal. L. CONDENSER REMOVAL 1. Remove the radiator (Refer Radiator removal process). 2. Loosen and remove the 4 condenser mounting bolts on the radiator and separate out the con- denser. CAUTION Never leave the condenser lines open immediately cover them with caps, otherwise the desiccant which is in-built in the condenser may absorb the moisture from surrounding air and get contaminated. FITMENT Follow the reverse procedure of removal. M. CHILLER UNIT Type – Plate type chiller REMOVAL 1. Open the bonnet of the vehicle. 2. Remove Aux Battery negative terminal and Put masking tape on Aux Battery negative terminal & cable. 3. Discharge the refrigerant using standard recov- ering equipment. (Refer maintenance section.) 4. Drain coolant from BCS system by disconnecting coolant hose from HV battery. 5. Remove Electrical connection on chiller unit. 6. Remove the mounting nut and disconnect the Suction line and the discharge pipes from chiller TXV and take out AC pipes.